Description
EPCO’s Fixture Bracket RetroFit Conversion Kits provide fast, cost-effective LED retrofits for older T12 or T8 fluorescent fixtures in commercial, industrial, and institutional facilities. Designed for Type B Single-End Powered T8 LEDs, these kits reduce energy consumption up to 30%, shorten installation time, and improve lighting quality while reusing the existing fixture housing. Ideal for energy-efficiency projects, utility rebate upgrades, and sustainable facility improvements.
BENEFITS
- Reduce Energy Costs: Upgraded LED systems consume up to 30% less energy, with potential initial savings of 40% or more.
- Labor and Installation Savings: Retrofitting is half the time and cost compared to installing new lighting. Installation time can be reduced by up to 25%.
- Quick Payback: Most installations achieve payback periods from 15 months to 3 years.
- Enhanced Lighting Quality: Improves the look and feel of your commercial, industrial, or institutional space.
- Sustainable: Ongoing energy savings and minimal job site waste.
- Simplified Upgrade: Easy, budget-conscious solution for building owners and facility managers seeking efficient lighting improvements.
FEATURES
- Energy-Efficient Upgrade: Converts T12 or T8 magnetic ballast fluorescent fixtures to T8 LED strip fixtures.
- Multiple Configurations:
- Standard Kits: 4-foot and 8-foot lengths.
- Pre-Wired Kits: 4-foot and 8-foot lengths with supply line and luminaire disconnect included.
- Type B Single-End Powered Compatibility: Specifically designed for UL 1598C classified T8 LED Tubes.
- Easy Integration: Compatible with automatic lighting controls and occupancy sensors.
- Reuses Existing Fixture Housing: Reduces material waste and installation disruption.
- Minimal Rewiring Required: Streamlined installation process for faster project completion.
TYPICAL APPLICATIONS
- Commercial Buildings: Offices, retail stores, and warehouses.
- Industrial Facilities: Manufacturing plants, factories, and workshops.
- Institutional Buildings: Schools, hospitals, and government facilities.
- Energy-Efficiency Projects: Utility rebate-eligible retrofits or sustainability initiatives.
- Maintenance & Upgrade Projects: Facilities seeking fast, cost-effective lighting upgrades without full fixture replacement.
NOTES
- Required LED Tubes: P/Ns 14070, 14070B, 14071, and 14076 require Type B Single-End Powered Bi-Pin T8 LED Tubes classified to UL Standard 1598C. Line voltage must connect to the powered end.
- Pre-Wired Kits: P/Ns 14073, 14073B, 14074, and 14074B require connection to HOT and Neutral (Black and White) conductors on the wiring harness luminaire disconnect.
- Bulk Orders: P/Ns 14070B, 14073B, 14074B, and 14080 must be ordered in quantities of twenty (20).
Part Numbers
More Details
More Details
More Details
More Details
More Details
Warranty
EPCO Warrants the products described herein, will be furnished free from defects in material and workmanship for 1 year. Any exceptions will be indicated on the product or product packaging. EPCO’s sole obligation for any breach of warranty under the terms herein shall be, at our option, to repair or provide replacement for the Product to which such warranty is breached, or to return all payments made with respect to such Product.
This warranty is void if this product is installed improperly or installed in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under operating conditions or not in accordance with any labels or instructions.
The Purchaser in a written notice to Engineered Products Company’s Warranty Department must specify any Product(s) that is deemed to be defective within 1 year after receipt of such goods. Under no circumstances will Engineered Products Company be liable for loss of profits or incidental, indirect, consequential or special damages of any kind beyond the replacement cost of the defective merchandise.
Engineered Products Company shall not be liable for any losses arising from governmental action, an act of God, or the result of war, riot, strikes, civil commotion, sovereign conduct, or the act or conduct of any person or person not party to or associated with Engineered Products Company.
FAQ
What types of fluorescent fixtures can these retrofit kits convert?
EPCO Fixture Bracket RetroFit Conversion Kits convert T12 or T8 fluorescent fixtures with magnetic ballasts into energy-efficient T8 LED strip fixtures.
Are the kits compatible with automatic controls and occupancy sensors?
Yes. These retrofit kits easily integrate with occupancy sensors, daylight harvesting systems, and other automatic lighting controls for optimal energy management.
What configurations are available?
Two configurations are offered:
- Standard Kits: 4-foot and 8-foot kits.
- Pre-Wired Kits: 4-foot and 8-foot kits with supply line and luminaire disconnect included.
Which LED tubes are required?
Standard kits (P/Ns 14070, 14070B, 14071, 14076) require Type B Single-End Powered Bi-Pin T8 LED Tubes classified to UL Standard 1598C. Pre-wired kits (P/Ns 14073, 14073B, 14074, 14074B) require connection to HOT and Neutral conductors on the supplied wiring harness.
How much energy savings can I expect?
Retrofitted fixtures consume up to 30% less energy, with initial energy savings of 40% or more depending on usage and controls.
How long is the payback period for a retrofit?
Most installations achieve payback periods from 15 months to 3 years, making these kits a cost-effective solution for energy efficiency upgrades.
Do I need to replace the entire fixture?
No. EPCO retrofit kits reuse the existing fixture housing, minimizing waste, labor, and material costs.
Can these kits be used for large commercial or industrial facilities?
Absolutely. They are ideal for commercial, industrial, institutional, and multi-tenant facilities seeking to reduce energy costs and improve lighting quality efficiently.