Solving the Conduit Fill Conundrum

When asked if we could build a Custom Fixture Whip in 3/8” Steel Flex with 3-12 AWG wires and 2-16 AWG wires, I wondered if this amount of wire would fit inside our 3/8” Steel Flex—even with an External Connector. So I consulted my 2014 NEC code book, and coincidentally, this very topic arose during a recent continuing education credits course I took.

According to my calculation, the total cross-sectional area of the five conductors exceeded the allowable 40% fill rate of the 3/8” conduit. I concluded that we would have to use 1/2” Steel Flex.

As a result of this inquiry, I thought it might be valuable to share this table—Maximum Number of Insulated Conductors in 3/8-inch Flexible Metal Conduit.

If you’ve got questions, we’re here to help figure out the answers. Call Tim Nelson, EPCO Inside Sales Supervisor and Master Electrician – 800.336.1976 or Email – sales@engproducts.com.

Blog Categories

Ask the Electrician
Ask the Engineer
Case Studies
Electrical News & Trends
Fixture Whips
Ground Bonding
Lighting
Notes from the Corner Office
Product Accessories
Splice Kits/Heat Shrink Tubing
Uncategorized
Video
Footer Menu
  • Products
    • Lighting
    • Ground Bonding
    • Splice Kits / Heat Shrink Tubing
    • Product Accessories
  • Resources
    • Literature
    • Data Sheets
    • Installation Guides
    • Videos
    • NEC References
    • MSDS Sheets
    • Federal Legislation
  • Customer Service
    • Customer and Technical Support
    • Literature Request
    • Find a Sales Rep
    • Find a Distributor
    • Newsletter Sign Up
  • About
    • Who We Are
    • Press Releases
    • Employment Opportunities
    • Why Buy from EPCO?
  • Blog
    • Blog Home
    • Ask the Electrician
    • Ask the Engineer
    • Electrical News & Trends
    • Case Studies
Phone: 800.336.1976   |   Fax: 800.336.2801   |   5401 Smetana Drive Minnetonka, Minnesota 55343   |   Login »
Follow Us!