T8 Retrofit Conversion Kits

T8 Retrofit Conversion Kits

Converts older 4-foot and 8-foot T8 or T12 strip light fixtures into energy efficient T8 light fixtures. Each kit includes T8 Bi-Pin Lamp Sockets, T8 Retrofit Bracket Socket Plates and Self-Tapping Screws.

  • Complies with UL Standard 1598B and 1598C.
  • Pre-wired conversion kit bracket; the installer only needs to complete the bracket installation and ballast lead terminations.
  • Pre-painted with smooth, glossy, highly reflective white paint.
  • Includes pre-drilled holes for installing Ballast Cover or Reflectors.

Features and Benefits

  • Easily retrofits existing T12 fluorescent light fixtures to energy efficient and high lumen output T8 light fixtures.
  • Suitable for use with all manufacturers' T8 lamps.
  • Lowers maintenance costs due to less frequent T12 lamp replacement.
  • High efficiency T8 lamps use 40% fewer watts, produce 40% less heat, and output 10% more lumens when compared to older magnetic T12 light fixtures.
  • Building owners and facility managers can significantly increase their energy savings by:
    • Reducing your kWh consumption to 40% or more. More over they can reduce the demand (kW) charge, where applicable, which in many cases can account for 50% of the monthly electrical bill.
    • Reducing the HVAC costs by removing a significant amount of the excess heat generated by existing inefficient T12 fluorescent lighting.
    • Reduces the negative side effects of poor light quality. Worker productivity can increase 9-16% or more as the result of improved light quality.
  • P/Ns: 14070, 14071, 14076 and 14077 may be suitable for use with Linear LED Retrofit Lighting. These designated Retrofit Conversion Kits part numbers fitted with "non-shunted" lamp holders are suitable for use with linear LED engines (T8 shaped LED tubes) as long as the LED engine is classified per UL 1598C.

NOTE: FOR USE WITH INSTANT START BALLAST ONLY EXCEPT P/NS: 14070 14071, 14076 AND 14077! Accommodates fixture housing widths between 4.25" and 5.0".  Energy consumption and savings will vary based on the hours per day, the number of operating days per year, the energy cost from your local service provider, and lamp cost.


Catalog
Number
UPC
Number
Description Image Preview
(Click Icon)
Order
Unit
Unit
Qty
Unit
Pkg
Unit/
Case
TI Case
Qty
Min
Order Qty
MM
Req
Ship wt
(Lbs)
14080 14080 Standard Ballast Cover: 4-FT - White, 1/4 Turn Retainer Clips, for 4.25" Wide Fixture Housing ONLY Standard Ballast Cover: 4-FT - White, 1/4 Turn Retainer Clips, for 4.25\ EA 1 BX 20 20 20 Yes 27
14050 14050 T8 Retrofit Conversion Kit: for an 8-FT Fixture, 4 Lamp T8 Retrofit Conversion Kit: for an 8-FT Fixture, 4 Lamp EA 1 BG 10 10 10 Yes 14
14051 14051 T8 Retrofit Conversion Kit: for an 8-FT Fixture, 4 Lamp, with Jumper Cable and WAGO Connector T8 Retrofit Conversion Kit: for an 8-FT Fixture, 4 Lamp, with Jumper Cable and WAGO Connector EA 1 BG 10 10 10 Yes 10
14055 14055 T8 Retrofit Conversion Kit: for an 8-FT Fixture, 2 Lamp T8 Retrofit Conversion Kit: for an 8-FT Fixture, 2 Lamp EA 1 BG 10 10 10 Yes 14
14056 14056 T8 Retrofit Conversion Kit: for an 8-FT Fixture, 2 Lamp, with Jumper Wire and WAGO Connector T8 Retrofit Conversion Kit: for an 8-FT Fixture, 2 Lamp, with Jumper Wire and WAGO Connector EA 1 BG 10 10 10 Yes 14
14057 14057 T8 Retrofit Conversion Kit: for a 4-FT Fixture, 1 Lamp T8 Retrofit Conversion Kit: for a 4-FT Fixture, 1 Lamp EA 1 BG 10 10 10 No 14
14070 14070 T8 Retrofit Conversion Kit: for 8-FT Fixture, 4 Lamp, to be used with Programmed Start Ballast ONLY T8 Retrofit Conversion Kit: for 8-FT Fixture, 4 Lamp, to be used with Programmed Start Ballast ONLY EA 1 BG 10 10 10 Yes 14
14076 14076 T8 Retrofit Conversion Kit: for 4-FT, 2 Lamp, to be used with Programmed Start Ballast ONLY T8 Retrofit Conversion Kit: for 4-FT, 2 Lamp, to be used with Programmed Start Ballast ONLY EA 1 BG 10 10 10 No 14
14085 14085 1/4 Turn Retainer Clips: for Ballast Cover and Reflectors 1/4 Turn Retainer Clips: for Ballast Cover and Reflectors EA 1 BG 40 40 40 Yes 1
14090 14090 T8 Retrofit Conversion Kit: for a 4-FT Fixture, 2 Lamp T8 Retrofit Conversion Kit: for a 4-FT Fixture, 2 Lamp EA 1 BG 10 10 10 Yes 14
14091 14091 White Reflector: 6-inch - Nominal Width 5.40", with 1/4 Turn Retainer Clips White Reflector: 6-inch - Nominal Width 5.40\ EA 1 BX 20 20 20 Yes 14
14092 14092 Specular Reflector: 6-inch - Nominal Width 5.40", with 1/4 Turn Retainer Clips Specular Reflector: 6-inch - Nominal Width 5.40\ EA 1 BX 20 20 20 Yes 14
14095 14095 White Reflector: 10-inch - Nominal Width 9.25", with 1/4 Turn Retainer Clips White Reflector: 10-inch - Nominal Width 9.25\ EA 1 BX 20 20 20 Yes 16
14096 14096 Specular Reflector: 10-Inch - Nominal Width 9.25", with 1/4 Turn Retainer Clips Specular Reflector: 10-Inch - Nominal Width 9.25\ EA 1 BX 20 20 20 Yes 16
14071 14071 T8 Retrofit Conversion Kit: for 8-FT Fixture, 2 Lamp, to be used with Programmed Start Ballast T8 Retrofit Conversion Kit: for 8-FT Fixture, 2 Lamp, to be used with Programmed Start Ballast EA 1 BG 10 10 10 Yes 14
14077 14077 T8 Retrofit Conversion Kit: for 4-FT Fixture, 1 Lamp, to be used with Programmed Start Ballast ONLY T8 Retrofit Conversion Kit: for 4-FT Fixture, 1 Lamp, to be used with Programmed Start Ballast ONLY EA 1 BG 10 10 10 Yes 14